    纯水离线总有机碳测量仪厂*   安全措施忠告:

    1.请保证电源可靠接地;

    2.电源电缆线的线径 > 2.5 mm2;

    3.请勿将仪器浸泡于水或其它液体中

    纯水离线总有机碳测量仪厂*  The principle of determining TOC value by subtraction method

    Water samples are injected into high-temperature combustion tubes (900 ℃) and low-temperature reaction tubes (150 ℃), respectively. The water sample passing through the high-temperature combustion tube is subjected to high-temperature catalytic oxidation, converting both organic compounds and inorganic carbonates into carbon dioxide. The water sample passing through the reaction tube is acidified, causing the decomposition of inorganic carbonate into carbon dioxide. The generated carbon dioxide is sequentially introduced into a non dispersed infrared detector to measure the total carbon (TC) and inorganic carbon (IC) in the water, respectively. The difference between total carbon and inorganic carbon is called total organic carbon (TOC).

    The principle of direct method for determining TOC value

    After acidification and aeration of the water sample, various carbonates are decomposed to generate carbon dioxide and expelled, which is then injected into a high-temperature combustion tube to directly determine total organic carbon. However, due to the loss of volatile organic compounds in the water sample during the aeration process, resulting in measurement errors, the measurement results are only the organic carbon values that cannot be blown out.

    Conductivity method

    Use a UV lamp to convert organic matter in water into carbon dioxide, which dissolves in water to form carbonate ions. The conductivity is measured before and after the organic matter conversion, and the increased carbonate content can be calculated by the difference in conductivity, which can then calculate the TOC in water.

    水样中TOC的分析步骤

    1.试剂准备

    (1)邻苯二甲酸氢钾(KHC8H4O4):基准试剂

    (2)无水碳酸钠:基准试剂

    (3)碳酸氢钠:基准试剂

    (4)无二氧化碳蒸馏水

    2.标准贮备液的制备

    (1) 有机碳标准贮备液:称取干燥后的适量KHC8H4O4,用水稀释,*般贮备液的浓度为400mg/L碳。

    (2) 无机碳标准贮备液:称取干燥后适量比例的碳酸钠和碳酸氢钠,用水稀释,*般贮备液的浓度为400mg/L无机碳。

    3.有机碳、无机碳标准溶液的配制

    从各自的贮备液中按要求稀释得来。

    4.校准曲线的绘制

    由标准溶液逐*稀释成不同浓度的有机碳、无机碳标准系列溶液,分别注入燃烧管和反应管,测量记录仪上的吸收峰高,与对应的浓度作图,绘制校准曲线。

    5.水样测定

    取适量水样注入TOC仪器进行测定,所得峰高从标准曲线上可读出相应的浓度,或由仪器自动计算出结果。

    6. 计算

    差减法:总有机碳(mg/L)=总碳-无机碳

    直接法:总有机碳(mg/L)=总碳

     

    故障分析与排除

     

    序号

    故障现象

    原因分析

    排除方法

    1

    开电源后屏幕无显示

    1、查看保险丝是否损毁;

    2、电源线插头与机器插口是否有松动

    1、更换保险丝  

    2、插紧电源线

    2

    检测数据不稳定(测同*水样时连续两个值相差过大)或误差过大

    检查进管与液管有无气泡,进管与液管有无压过的痕迹

    1、更换有压痕的进管或液管

    2、用纯水冲洗管路

    3

    检测数值偏低过多

    UV灯使用期限是否已到

    更换UV灯

    4

    按键失灵无反应

    1、检查按键是否有破损,有无液体流入;

    2、长期使用或操作不当造成按键失去弹性而短路

    更换按键

    5

    仪器内部有异常的声音

    1、判断是否有异物掉入仪器内;

    2、电机转动是否正常

    请专业人员修理

    6

    蜂鸣器叫

    1、短叫*声表明所测值高于仪器设定的上限值;

    2、长叫可能是主板故障

    1、所测样有问题来源

    2、请专业人员修理

    7

    查询数据时死机

    仪器“参数设置”项下设置为打印”,但未接打印机查询记录时搜索不到打印机

    1、重启,“参数设置”项下设置为不打印

    2、连接打印机

    8

    管不出水

    1、管路堵塞;

    2、泵管已磨损

    1、用小注射器抽水口

    2、换泵管

    零点校准

    仪器校准的目的是为了减小传感器的零点漂移,并对其测试曲线进行修订,对于

    保证仪器测试结果的准确性有非常重要的意义。

    校准周期可以根据具体使用情况而定,建议更换紫外灯或仪器使用半年以后校准

    *次。出现数据分析的结果偏差较大时,也可进行校验。

    仪器在校准过程过程中,将用到两种标准液,*种是总有机碳低于 0.1ppm,电

    导率低于 1.0μs/cm(25℃)的高纯水作为零点水;另*种是 0.5ppm 的标准蔗糖溶液。

    a) 零点水和标准溶液要采用密闭容器内盛放,容器的顶空要尽量小,密封

    口打开后要尽快测试。

    b) 配制校准溶液之前,蔗糖标准品必须在 105℃(221°F)环境下干燥

    至恒重。

    低浓度高纯水在空气中暴露超过*小时,会因溶解了空气中的二氧化碳而

    使电导率值明显增大。

    Replace UV lamp

    When replacing UV lamps, care must be taken to avoid damage to the lamp tube and its surrounding spiral quartz tubes.

    When providing customers with new UV lamp tubes, a pair of gloves is included for installation to avoid damage to the surface and screws of the UV lamp tubes

    Fingerprints are left on the surface of the rotating quartz tube. Fingerprints will absorb UV light and reduce the oxidation performance of the oxidation reactor. Simultaneously

    Before installing a new UV lamp, ethanol can be used to remove fingerprints and dirt, ensuring the transparency of the UV lamp surface.

    Specific steps for replacing UV lamps:

    Turn off the main power switch and unplug the power cord.

    Unscrew the screws on the rear cover plate of the instrument case and open the rear cover plate.

    Pull out the power cord plug connecting the lamp tube, loosen the locking nut of the lamp tube holder, and slowly pull out the lamp tube.

    Replace the lamp with a new one and adjust the effective position of the lamp in the spiral quartz tube, and tighten the locking nut.

    Insert the power cord plug of the lamp tube and tighten the screws on the back cover of the chassis until the replacement is complete.

    If there are any issues when replacing the above components, please contact the instrument manufacturer for resolution.易耗品更换周期

    UV灯和蠕动泵管可以从本公司购买。UV灯为185nm、254nm双波长紫外灯,蠕动泵管为进口泵管,具有高品质和良好的稳定性。易耗品更换周期参考表5.1。

    表5.1  易耗品维护/更换表

    部件名称

    更换周期*

    UV灯

    12个月

    蠕动泵管

    12个月

     

    系统组成

    TOC分析仪的组成包括以下7个主要部分:

    ① 在线检测装置(在线型仪器配备)

    ② 样品蠕动泵

    ③ 分流器

    ④ 氧化反应器

    ⑤ 二氧化碳传感器

        ⑥ 微处理控制器和电子线路板

    ⑦ 输出接口

    水中TOC的监测

    我们的生活离不开水,若相当多的有机污染物存在于水中,将直接影响水体的质量,对我们的生活和生产造成危害,因此水和废水的监测,越来越引起人们的重视。其中水体中总有机碳(TOC)含量的检测,日益引起关注。它是以碳含量表示水体中有机物质总量的综合指标。TOC的测定*般采用燃烧法,此法能将水样中有机物全部氧化,可以很直接地用来表示有机物的总量。因而它被作为评价水体中有机物污染程度的*项重要参考指标。

    主要技术参数

    (*)电    源:220V±22V

    (二)电源频率:50Hz±1Hz

    (三)额定功率:100W

    (四)基本尺寸:44cm×18cm×26cm

    (五)检测*限:0.001mg/L

    (六)检测精度:±5%

    (七)检测范围:0.001mg/L~1.000mg/L

    (八)分析时间:4min

    (九)响应时间:15 min以内

    (十)样品温度:1-95℃

    (十*)环境温度:10-40℃    温度变化在±5℃/d以内

    (十二)内部样品流速:0.5 ml/min

    装箱清单

     

    试验主机

    *台

    采集管

    两条

    电源线

    *条

    控制系统

    *套

    数据采集系统

    *套

    产品使用说明书

    *份

    产品合格证、保修卡

    *份

    主要产品有:

    拉力试验机,                      塑料球压痕硬度计

    维卡热变形试验仪,                体积表面电阻率测试仪

    海绵泡沫落球回弹试验机,          海绵泡沫拉伸强度试验机

    耐压试验机,                  介电常数测试仪

    海绵泡沫压陷硬度测验仪,          介质损耗测试仪

    海绵泡沫切割机,                  哑铃制样机

    海绵泡沫疲劳压陷试验机,          薄膜冲击试验机

    熔融指数仪,                      无转子硫化仪

    电压击穿试验仪,                  摩擦系数仪

    低温脆性冲击试验仪                阿克隆磨耗试验机等。

     

    您可以通过以下类目找到类似信息:

     

    免责声明:以上所展示的信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责。商品网对此不承担任何责任。

    友情提醒:为规避购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量!